Diesel Generators
Configuration
When selecting diesel generators, the first question is what is the size of the load it is going to supply and what are the amounts of both running loads (KW) and starting loads (KVAr). What type of loads are going to be supplied?. Is there for example UPS loads or heavy motor loads?. Is the load steady load or intermittent switching on and off load?. This is known as Sizing of diesel generators for site loads. The second question will be is the generator going to run as standby for the mains, or it is going to run as prime power source. The third question is for how long is this investment is going to last?. In other words are we going to select a heavy duty genset to last more than 5 years or it is going to be for few years. Where the genset is going to be installed and under which environmental conditions. is there any noise restrictions?. is there any space limitation?. What voltage and frequency this generator going to generate?. All these considerations affect the final decision of which diesel engine prime over is going to be and which alternator is going to be driven and what is the KW rating of this genset and how it will be installed, what control system is going to be installed, level of protections, cooling system, acoustics ...etc. This is known as diesel generator configuration for site loads. |
|
Sizing
As part of configuration process of a genset is to answer the question: What is the size of this genset in terms of KW rating and what is its reactive capability to withstand the transient loads. The sizing process is started always by sizing the site load and defining the total running loads in KW and starting loads in KVA and then apply the other site load criteria such as maximum allowable voltage dip, load factor and the future expansion to calculate the size of the generator(s). It should be emphasized here that the power factor is controlled by the load and it affects the generator by pulling more currents as the power factor drops. Loads which have high starting KVA's are simply have low starting power factors. When sizing gensets it is advisable always to limit the starting KVA of the load by using lower voltage starting methods like star/delta or transformer tap or if this is not possible use sequencing. This is to switch the big starting KVA loads in sequence of 15 to 30 seconds intervals and not together. NECSize 2008 software can calculate the site load KW's and starting KVA's |
|
Design
After sizing the diesel generator and configuring all the required auxiliary systems and controls here it comes the next step which is how to realize this?. What are the different equipment and components which all together make the genset and how they are put together as one system to give the required genset with its pre-defined specifications. This is known as design process. Some manufacturers design some or all of the genset supporting systems such as the skid bases, control panels, circuit breaker panels, exhaust system, fuel tanks, weather enclosures,....etc for which these manufacturers should have engineering design office and produce shop floor drawings and bills of materials. They should have quality control as after sales service system. design include electrical control schematic drawings, wiring diagrams, control panels and switchgear general arrangement drawings, components layout drawings, single line diagrams, wires and cables schedule, PLC ladder logic diagrams, controllers setup files, skid base production drawings, genset general arrangement drawing, radiator and pipes layouts, P&ID, power house layout drawing, genset enclosure drawing, genset trailer drawing and many other detailed drawings which will be used by the manufacturer or his subcontractors for manufacturing and/or installation purposes. NEC offers one of the best courses on diesel generators worldwide. |
|
Manufacturing & Assembly
The manufacturing process starts from receiving the design drawings and materials including the major equipment (engine and alternator). The manufacturing process differs from one manufacturer to another. While some manufacturers do everything or most of the work in their own factory, others may outsource some or most of the work to more specialized manufacturers who can do it more economically and/or faster. This can include for example steel fabrication work for skid bases, fuel tanks and weather enclosures. Some manufacturers even outsource the control panels and switchgear and they monitor their quality and do assembling and test.
The manufacturing process starts from receiving the design drawings and materials including the major equipment (engine and alternator). The manufacturing process differs from one manufacturer to another. While some manufacturers do everything or most of the work in their own factory, others may outsource some or most of the work to more specialized manufacturers who can do it more economically and/or faster. This can include for example steel fabrication work for skid bases, fuel tanks and weather enclosures. Some manufacturers even outsource the control panels and switchgear and they monitor their quality and do assembling and test.
Diesel Engine
The diesel engine is the most important part of the genset. It is the prime mover that drives the generator (alternator) to produce electricity. All diesel engines are similar to each other in the concept but they differ in many aspects such as the number of cylinders, if the cylinders are line or V-type, how the fuel is delivered to the cylinders, governing system, cooling system, air charging system, air intake system, rotational speed and recently the engine tier for COx and NOx emissions. All these details affect the decision of which engine to use and which performance is expected. Engines are rated in KW or HP. Their performance is measured in their fuel consumption in liters or gallons per KWh produced, its thermal efficiency, noise level, lube oil consumption and exhaust gas emissions.
The diesel engine is the most important part of the genset. It is the prime mover that drives the generator (alternator) to produce electricity. All diesel engines are similar to each other in the concept but they differ in many aspects such as the number of cylinders, if the cylinders are line or V-type, how the fuel is delivered to the cylinders, governing system, cooling system, air charging system, air intake system, rotational speed and recently the engine tier for COx and NOx emissions. All these details affect the decision of which engine to use and which performance is expected. Engines are rated in KW or HP. Their performance is measured in their fuel consumption in liters or gallons per KWh produced, its thermal efficiency, noise level, lube oil consumption and exhaust gas emissions.
AC Generator (Alternator)
The ac generator or alternator is the second major part of the genset. Nowadays most if not all of the alternators are brushless type with rotating excitation system. The alternator is selected during the configuration process. It should be matched mechanically to the diesel engine. Electrically the alternator should be selected to provide the required KW at the specified voltage, frequency, ambient temperature, altitude and it should be capable to withstand the transient loads without exceeding the maximum allowable voltage dips. Normally the automatic voltage regulator (AVR) is supplied as part of the alternator to ensure the compatibility. The brushless alternators use rotating exciter generator to generate the excitation (magnetization) current and voltage required by the main rotor to be excited (magnetized). The AVR controls the amount of excitation given to the rotor based on sensing the generator output voltage. Alternators speed should match the diesel engine speed. The lower the speed the higher the number of rotor poles. This is to maintain fixed 50 Hz or 60 Hz regardless of the rotation speed. NEC offers excellent course on AC generators and excitation system.
The ac generator or alternator is the second major part of the genset. Nowadays most if not all of the alternators are brushless type with rotating excitation system. The alternator is selected during the configuration process. It should be matched mechanically to the diesel engine. Electrically the alternator should be selected to provide the required KW at the specified voltage, frequency, ambient temperature, altitude and it should be capable to withstand the transient loads without exceeding the maximum allowable voltage dips. Normally the automatic voltage regulator (AVR) is supplied as part of the alternator to ensure the compatibility. The brushless alternators use rotating exciter generator to generate the excitation (magnetization) current and voltage required by the main rotor to be excited (magnetized). The AVR controls the amount of excitation given to the rotor based on sensing the generator output voltage. Alternators speed should match the diesel engine speed. The lower the speed the higher the number of rotor poles. This is to maintain fixed 50 Hz or 60 Hz regardless of the rotation speed. NEC offers excellent course on AC generators and excitation system.
Speed Governing
The two main parameters we must control in the diesel generator sets are speed and voltage. Controlling the speed is controlling the diesel engine prime mover via controlling the fuel. On the other hand controlling the voltage is controlling the AC generator (alternator) via controlling the excitation of the rotor (magnetization of the rotor). Speed governing or some time we call it speed control is like any other feedback control system. It consists of sensing part that measure the running speed of the diesel engine (magnetic pickups). Then the speed controller compares the actual running speed from the magnetic pickup with the set reference speed and produces an error. This error is then amplified and converted to an output signal to raise or lower the speed via the governor actuator. This is electronic type. The most famous control is known as PID (Proportional, Integral and Derivative). Governors can also be mechanical hydraulic type.
The two main parameters we must control in the diesel generator sets are speed and voltage. Controlling the speed is controlling the diesel engine prime mover via controlling the fuel. On the other hand controlling the voltage is controlling the AC generator (alternator) via controlling the excitation of the rotor (magnetization of the rotor). Speed governing or some time we call it speed control is like any other feedback control system. It consists of sensing part that measure the running speed of the diesel engine (magnetic pickups). Then the speed controller compares the actual running speed from the magnetic pickup with the set reference speed and produces an error. This error is then amplified and converted to an output signal to raise or lower the speed via the governor actuator. This is electronic type. The most famous control is known as PID (Proportional, Integral and Derivative). Governors can also be mechanical hydraulic type.
Excitation (Magnetization) Control
As mentioned elsewhere the excitation is simply magnetizing the rotor to produce magnetic field. During the rotation of the rotor the field flux lines intersect with the stator windings and electromotive force (emf) will be generated accordingly. Most of the alternators used nowadays are brushless type, where the DC current required to magnetize the rotor is produced by the exciter generator and then rectified using rotating rectifiers. To control the amount of excitation we need to control the exciter generator. The voltage regulator is used to sense the output voltage of the alternator and then compares it with the setting to produce the error. This error is amplified and modulated to control the field of the exciter. In some applications where the generator is to run in parallel with the mains the generator reactive power in this case must be controlled so that the generator will not be pulled to an overload situation. PF control is used.
As mentioned elsewhere the excitation is simply magnetizing the rotor to produce magnetic field. During the rotation of the rotor the field flux lines intersect with the stator windings and electromotive force (emf) will be generated accordingly. Most of the alternators used nowadays are brushless type, where the DC current required to magnetize the rotor is produced by the exciter generator and then rectified using rotating rectifiers. To control the amount of excitation we need to control the exciter generator. The voltage regulator is used to sense the output voltage of the alternator and then compares it with the setting to produce the error. This error is amplified and modulated to control the field of the exciter. In some applications where the generator is to run in parallel with the mains the generator reactive power in this case must be controlled so that the generator will not be pulled to an overload situation. PF control is used.
Engine Auxiliary Systems and Instrumentation
Each genset has auxiliary systems to support its functions. Most if not all of these systems are attached to the diesel engine. When the diesel engine burns the diesel, fuel it Cooling system, fuel system, lubrication system, air intake system, exhaust system. Each one of these systems can vary in the design specs even for the same engine; this is depending on the application and configuration of the genset. Each of these systems has instrumentation to measure and indicate the operating parameters.
Each genset has auxiliary systems to support its functions. Most if not all of these systems are attached to the diesel engine. When the diesel engine burns the diesel, fuel it Cooling system, fuel system, lubrication system, air intake system, exhaust system. Each one of these systems can vary in the design specs even for the same engine; this is depending on the application and configuration of the genset. Each of these systems has instrumentation to measure and indicate the operating parameters.
Safeties and Protection
The genset consists of mechanical part represented by the diesel engine and electrical part represented by the AC generator (alternator). Each of these two major equipment must be properly protected against abnormal operating parameters. There are of course mechanical parameters and electrical parameters. For example the oil pressure and water temperature are two of the mechanical parameters while the AC current and voltage are two of the electrical parameters which we must protect the genset against abnormal values.
The genset consists of mechanical part represented by the diesel engine and electrical part represented by the AC generator (alternator). Each of these two major equipment must be properly protected against abnormal operating parameters. There are of course mechanical parameters and electrical parameters. For example the oil pressure and water temperature are two of the mechanical parameters while the AC current and voltage are two of the electrical parameters which we must protect the genset against abnormal values.
Control System
Each genset must have a control system; the control system consists of sensors and actuators connected to a control panel. The control panel normally has a controller, which does the start, and stop of the genset and protect the genset against abnormal operating parameters. The control panel can have lot of optional controls, protection and metering devices as per the design to suit the applications and configuration of the genset to meet customer's specs.
Each genset must have a control system; the control system consists of sensors and actuators connected to a control panel. The control panel normally has a controller, which does the start, and stop of the genset and protect the genset against abnormal operating parameters. The control panel can have lot of optional controls, protection and metering devices as per the design to suit the applications and configuration of the genset to meet customer's specs.
Switchgear and Power Distribution
The switchgear is the electrical part of the genset, which connects and disconnect the genset output electrical power to the load. The switchgear is usually a circuit breaker or a contactor.
The switchgear is the electrical part of the genset, which connects and disconnect the genset output electrical power to the load. The switchgear is usually a circuit breaker or a contactor.
Testing Diesel Generators
Each manufactured diesel generator set is normally tested at the factory according to the application and configuration of the genset and following design criteria. The purpose of the factory test is to validate the genset design to meet the specified criteria. This includes functional test, load test and safeties and protections test.
Each manufactured diesel generator set is normally tested at the factory according to the application and configuration of the genset and following design criteria. The purpose of the factory test is to validate the genset design to meet the specified criteria. This includes functional test, load test and safeties and protections test.
Trouble-Shooting Diesel Generators
When diesel generator sets operate, whether in standby mode or as prime power they are expected to encounter some mechanical or electrical problems, which could cause them to either shutdown or their performance to degrade. Genset problems vary from simple electrical wiring faults to major engine problems. Trouble-shooting the problems in the gensets is simply answering the question: what caused this alarm, or what caused this shutdown or what caused this erratic behavior. Trouble-shooting is a process starting with collecting the information then defining the problem. After defining the problem list all, the possible causes of the problem and finally select the solution or solutions, which eliminate the problem or problems taking into consideration the economics and reliability.
When diesel generator sets operate, whether in standby mode or as prime power they are expected to encounter some mechanical or electrical problems, which could cause them to either shutdown or their performance to degrade. Genset problems vary from simple electrical wiring faults to major engine problems. Trouble-shooting the problems in the gensets is simply answering the question: what caused this alarm, or what caused this shutdown or what caused this erratic behavior. Trouble-shooting is a process starting with collecting the information then defining the problem. After defining the problem list all, the possible causes of the problem and finally select the solution or solutions, which eliminate the problem or problems taking into consideration the economics and reliability.
Vibration on Diesel Generators
Diesel generator sets can suffer from excessive vibration, which could cause failures and unwanted noise. Vibration can be linear or no linear. Sources of linear? Vibration can come from diesel engine internal combustion forces, miss alignment, unbalanced mounting and structural resonance. Nonlinear vibration can be caused from the shaft torsional forces. To control vibration we need to define its parameters, then we need to measure them and know the relationship between them and then we control them. Vibration main parameters are displacement, velocity, acceleration and frequency. These four (4) parameters are related to each other mathematically. Another parameter, which is necessary for analyzing the vibration and establishing its source, is the vibration order.
Diesel generator sets can suffer from excessive vibration, which could cause failures and unwanted noise. Vibration can be linear or no linear. Sources of linear? Vibration can come from diesel engine internal combustion forces, miss alignment, unbalanced mounting and structural resonance. Nonlinear vibration can be caused from the shaft torsional forces. To control vibration we need to define its parameters, then we need to measure them and know the relationship between them and then we control them. Vibration main parameters are displacement, velocity, acceleration and frequency. These four (4) parameters are related to each other mathematically. Another parameter, which is necessary for analyzing the vibration and establishing its source, is the vibration order.
Paralleling and Load Sharing Diesel Generators
Based on the results of the load sizing we may need to have more than one genset to operate in parallel to supply the load. When gensets operate in parallel they encounter problems not seen when they operate standalone. Some of these problems is how maintain the frequency of the system, how to share the site load, how to eliminate the reactive cross current and how to control the start and stop of these gensets when the site load increase or decrease and which genset will be the duty genset and which ones will be the non-duty and so on. These challenges require installing paralleling and load sharing control system with load demand control. To better understand the system we need to know for example the two modes of paralleling (droop and isochronous) and if the gensets are going to be paralleled with each other or with the mains and so on.
Based on the results of the load sizing we may need to have more than one genset to operate in parallel to supply the load. When gensets operate in parallel they encounter problems not seen when they operate standalone. Some of these problems is how maintain the frequency of the system, how to share the site load, how to eliminate the reactive cross current and how to control the start and stop of these gensets when the site load increase or decrease and which genset will be the duty genset and which ones will be the non-duty and so on. These challenges require installing paralleling and load sharing control system with load demand control. To better understand the system we need to know for example the two modes of paralleling (droop and isochronous) and if the gensets are going to be paralleled with each other or with the mains and so on.
Installation of Diesel Generators
Diesel generators can be as small as 10 KW and can be big to exceed 10000 KW. When these gensets are to be installed at the site there are lot of considerations to be taken. Gensets could be as heavy as 50 Ton or more. These need concrete foundations to be mounted on. They breathe air for combustion so fresh filtered air must be brought to them. Gensets need enough space so engine rooms must be designed to suit them. gensets require ventilation to reject the heat outside the engine rooms so inlet and outlet openings are to be integrated within the engine room design. Exhaust pipes need to be extended to outside the engine room; this has to be also taken into consideration. Ducts for power cables, control cables, fuel and coolant pipes could be needed and many more.
Diesel generators can be as small as 10 KW and can be big to exceed 10000 KW. When these gensets are to be installed at the site there are lot of considerations to be taken. Gensets could be as heavy as 50 Ton or more. These need concrete foundations to be mounted on. They breathe air for combustion so fresh filtered air must be brought to them. Gensets need enough space so engine rooms must be designed to suit them. gensets require ventilation to reject the heat outside the engine rooms so inlet and outlet openings are to be integrated within the engine room design. Exhaust pipes need to be extended to outside the engine room; this has to be also taken into consideration. Ducts for power cables, control cables, fuel and coolant pipes could be needed and many more.
Automatic Transfer Switches
When the diesel generator is used as standby for the mains power then it requires automatic transfer switchgear to transfer the load automatically from the mains power to the standby generator when the mains power fails. The ATS can be made or purchased in different styles. The open transition ATS is the most common one where it transfers the power from normal source to emergency source. The other style is the open transition bypass isolation ATS. This is similar to the first one except the ATS module can be completely isolated from the circuit when it malfunctions and two bypass switches are used to bypass either the normal power or the emergency power. The third famous style is the closed transition ATS. The difference between open and closed transition is that in the open transition the normal side switch opens before the emergency side switch is closed (break before make), while in the closed transition types the emergency side closes before the normal side opens (make before break). Other styles are also available.
When the diesel generator is used as standby for the mains power then it requires automatic transfer switchgear to transfer the load automatically from the mains power to the standby generator when the mains power fails. The ATS can be made or purchased in different styles. The open transition ATS is the most common one where it transfers the power from normal source to emergency source. The other style is the open transition bypass isolation ATS. This is similar to the first one except the ATS module can be completely isolated from the circuit when it malfunctions and two bypass switches are used to bypass either the normal power or the emergency power. The third famous style is the closed transition ATS. The difference between open and closed transition is that in the open transition the normal side switch opens before the emergency side switch is closed (break before make), while in the closed transition types the emergency side closes before the normal side opens (make before break). Other styles are also available.