NEC Acostix
NEC ACOSTIX ® is an Excel-based, programmed spreadsheet that helps engineers and manufacturers design acoustic enclosures and rooms, rectangular silencers, and acoustic louvers, and perform detailed sound calculations to verify their designs. It also enables designers to design sound attenuation for masonry wall rooms.
For more details:
Please contact us at support@najahengineering.com
Or WhatsApp at +962 79 806 1145
NEC Acostix software has been present in the market since 2007. We serve the industrial acoustics industry by providing customized solutions and customized tools that enable engineers to solve their noise problems easily.
NEC Acostix gives the best estimates for the sound insulation performance of the enclosure walls, masonry structures, sound attenuators, and louvers depending on the supplied data and properties of the materials.
Acostix and all its associated tools and modules are copyright-protected and registered trademarks worldwide in accordance with WIPCO, covering 195 countries worldwide.
Please refer to the End User Agreement for details.
Acostix Sub-Modules/Screens:
AX01: The Acostix® Exhaust Silencing Module. This module enables you to find suitable muffler insertion loss for a certain engine if you know the engine undamped exhaust noise SPL or SWL and your acceptance criteria, for example: 85 dBA at 1 meter.
AX02: The Acostix® Wall/Partitions Design/Masonry Wall (TL/SRI) Module. This module enables the designer to select the wall/windows/doors configuration and get individual transmission loss or overall transmission loss.
AX03: The Acostix® Duct Attenuator Design Module. This enables the designer to specify the dimensional details and acoustic materials specs of the attenuator to get the insertion loss (SIL/DIL). You can also simulate both friction and dynamic pressure losses through the duct.
AX04: The Acostix® Acoustic Louvers Design Module. You select one of the five different louver configurations, specify the dimensional details and acoustic materials, and then get the transmission loss (TL) and Noise Reduction (NR) along with simulated pressure loss.
AX05: The Acostix® Generator Sound Attenuation Design Configuration Module.
AX06: The Acostix® HVAC Acoustics Module. Enter the HVAC duct layout and dimensional and acoustical details, the AHU fan SWL, and the NC at the recipient room. The module calculates the sound attenuation required that can be achieved either by a sound attenuator or by increasing the duct attenuations. The module is in full compliance with ASHRAE and other related ISO and ASTM Standards.
AX07: The Acostix® Sound Calculations Module. This includes free-field and inside-room sound calculations, room average sound absorption coefficient, pressure drop for extended ducts, and SPL/SWL/airflow estimator for industrial machines. This module is essential along with any of the design modules.
General Features
All sound calculations meet relevant international standards: ASHRAE, ISO, and ASTM.
It calculates the required silencer attenuation IL to meet noise criteria.
It verifies any selected silencer to meet the noise criteria.
It designs acoustic walls or partitions to meet certain SRI/TL or certain noise criteria.
It changes the wall or partition steel thickness, acoustic filling properties, and any covering sheets that affect the absorption.
It takes into consideration free-field and reverberant room situations.
It designs rectangular attenuators by allowing you to flexibly adjust all design parameters, such as overall aperture size, number of splitters, splitter thickness, air gap between splitters, acoustic filling acoustic properties, perforation sheet configuration, air way length, airflow, flow velocity, etc.
It uses the latest algorithms to predict the acoustical performance of splitter ducts and silencers.
It takes into consideration inlet air temperature and temperature rises inside enclosures and through the radiators for discharge modules.
It differentiates between inlet and discharge air sound attenuations by considering the forward and backward flows.
It calculates pressure drop across all air inlet and discharge attenuation systems.
It designs acoustic louvers by allowing you to flexibly adjust the louver depth, louver blade shape, louver blade thickness, air gap between blades, louver acoustic filling properties, and perforation sheet. It also allows adjusting the free area percentage and airflow velocity.
It will provide the insertion loss for the designed attenuator and sound transmission loss for the louvers.
The software helps to calculate the best perforation that can achieve the best acoustic results.
The software can estimate diesel engine exhaust noise, surface noise, and airflow if not known.
The software calculates any noise in free field or inside reverberant rooms either as a single noise figure or over the octave band.
The software is equipped with a tool to calculate the wall or partition SRI (TL).
The software is equipped with a tool to calculate the average room absorption coefficient over the octave band. The software is also equipped with a tool to calculate pressure drops for different duct configurations and elbows.
NEC Acostix® is available in 3 main models: AX-S, AX-G, and AX-C. Each of them consists of several modules.


Acostix Software Models

AX-S (AX-00 Before): The General Acostix Software. This includes:
1. Walls Design and Sound Calculation Module
2. Baffled Attenuator Design and Sound Calculation Module
3. Baffled Attenuator IL and Pressure Drop Module
4. Acoustic Louvers Design and Sound Calculations Module
5. Exhaust Silencing Calculations Module
6. Room Reverberation Calculation Module
7. Perforation Sheet Calculators (TI and P%)
8. Free Field Sound Calculator
9. Reverberant Field Calculator
AX-G (AX-05 Before): The Acostix® AX-G Generator Sound Attenuation Design Package. Enter the SWL/SPL, dimensional details of the enclosure, dimensional details of the engine box, engine airflow data, and specify inlet and discharge dimensional details, doors, and windows. The module will give the enclosure wall SPL at the specified locations.
The module has a configuration screen where SWL/SPL data, airflow data, dimensions, temperature rises, etc. are all entered and used all across the other design modules. The package enables you to add exhaust ventilation fans in case a remote radiator system is used. The software gives the option to add up to three (3) inlet air system attenuations (attenuators and/or louvers).
You can select among more than 15 different design combinations of inlet and discharge air systems.
In addition to what was listed in AX-S above, the AX-G contains the following extra modules:
1. Configuration Module Where All the Generator Sound Data, Space Dimensions, and Airflows, As Well As Your Design Criteria, Are Set from This Screen
2. Can Select up to 3 Inlet Air Designs
3. Has an Extra Inlet Attenuator Module
4. Extra Discharge Attenuator Module
5. Extra Vertical Discharge Duct Option
6. Optional Vertical and Horizontal Ducting for the Generator
AX-C: All the Acostix® Design and Calculation Modules. It shall include the following modules: AX01, AX02, AX03, AX04, AX06, and AX07. This is a very powerful tool for designers of enclosures, attenuators, partitions, louvers, and silencers. Plus, they can do sound calculations inside and outside rooms/enclosures, including HVAC calculations in accordance with ASHRAE standards.
It has the same as AX-S, plus:
1. HVAC Room Side Calculation Module with Optional Primary and Secondary Attenuator Design
2. HVAC Atmospheric Side Calculation with Attenuator Design Option
Wall/Noise Barriers/Walls/Masonry Structures Design and SRI Calculations Tool
This module calculates the overall SRI (TL) of an acoustic wall or barrier that may contain doors and windows. The wall can be a masonry wall, single steel plate, or double steel plate with an air gap.
The sheet enables you to select the window and door dimensions, window glass and thickness configuration, and single-plate or double-plate configuration.
You need to enter the wall, door, and window dimensions. Then, the sheet will calculate the overall SRI of the assembly. This SRI can then be used as a known SRI Value to complete the wall design for enclosures or rooms, as stated in the wall design sheet above.
The module provides two types of structures: steel plates for enclosures and a masonry wall system.
Acoustic Louvers Design and Calculations:
Acostix designs the acoustic louvers to achieve the required acoustical (dB) and airflow (Pa) performance. You can select either to design inlet or discharge louvers. You can select among 5 different louver shapes. Other configurations can also be added upon request.
You have to enter the noise source SPL/SWL. You need to enter the selected acoustic filling materials’ absorption coefficients and thickness. You also need to select the perforation configuration. You have to specify the noise criteria and distance. You can select whether the room is reverberant or not and accordingly enter the absorption coefficient data, which can also be calculated by NEC Acostix tools.
Then, you can choose your design parameters, such as louver blade thickness, louver depth, louver blade spacing, and free area percentage of the overall aperture.
The software will display the resultant noise dB and air pressure drop for the selected design. You can fine-tune your design parameters to optimize the results. Of course, you can select to show or hide the calculations before you print the report.
The resultant transmission losses can vary from the ones obtained through tests by 1–3 dB in the low frequency and up to 3–5 dB in the higher frequencies, but the overall weighted dB will be 0–3 dBA. For more explanations and details, please contact support@najahengineering.com.
Acoustic Enclosure/Canopy/Room Design for Generator Sets and other Equipment
- The main module enables you to design the acoustic enclosure for diesel generator applications to meet certain noise ratings or criteria.
- The module is fed with the engine noise data, and then the designer will select the dimensional parameters of the wall, windows, inlet/discharge attenuation, and exhaust silencing to meet the criteria.
- The module allows you to enter either SPL or SWL data. You may also select between baffle-type attenuators and acoustic louvers for inlet and discharge aperture attenuations.
Cover Sheets Perforation Configurations and Calculations:
These tools allow you to find the Transparency Index (TI) and the open area percent of the perforated sheet used to cover the acoustic materials used in air ducts. These two parameters affect the acoustic performance of the perforated sheet and therefore affect the overall acoustic performance of the air duct assembly.
Of course, the higher the TI, the better it will be for the noise absorption of the acoustic filling, but this may not be possible due to the perforation sheet’s mechanical characteristics and strength.
You enter the perforation geometry, and the sheet will calculate the TI and P. These two parameters are inputs to the design of the walls, attenuators, and louvers.
The results of this sheet are the TI, P, and the access factor, which will be multiplied by the absorption coefficient of the acoustic material. In other words, this access factor downgrades the acoustic materials sound absorption capability.
Engine Exhaust Noise/Surface Noise and Airflow Estimator:
This tool allows the designer to estimate the engine exhaust noise SPL or SWL, engine surface noise SPL, and the inlet and discharge airflow.
You just enter the engine kW and then select from the drop-down lists the different characteristics of the engine, which must be known if the engine is physically available.
The software will display the engine exhaust and surface noise data over the 8 frequencies and the inlet and discharge airflow. These results can be used to design walls, attenuators, and louvers if the data is not available from the manufacturer.
Average Room Absorption Coefficient Calculation Tool
This tool helps designers calculate the room average sound absorption coefficient over the octave band.
The sheet allows you to enter the room dimensions, and, from the drop-down lists, you may select the sidewall, end walls, roof, and floor material. The results of this sheet will be the average absorption coefficients and the reverberation times. These results are very valuable when calculating sound from inside rooms through walls, attenuators, and louvers.
SPL vs. SWL
The difference between SPL and SWL: SPL is the sound pressure level = 20 log P/Pref. P is sound pressure in N/m2 and Pref = 20×10-6 N/m2, while SWL is the sound power level = 10 log W/Wref, where W is sound intensity in Watts and Wref = 10-12 Watt. The sound comes out from the source as SWL, and when it travels spherically, its intensity will be distributed over the sphere’s area, which makes it pressure SPL.
You may also need to do calculations of noise inside the room if the noise source is placed at a certain distance and you need to measure noise at a certain point inside the room, taking into consideration the reverberation time of the room.
This sheet does this. You can do this as a single figure, or you can enter the noise data of the source in SPL or SWL over the octave bands and enter all other details of the room.
The resulting information will be the noise level at the point you selected. You can select to show or hide the calculations before printing the report.
Pressure Drop Calculator Tool
Exhaust Noise Silencing and Calculations:
This module enables you to either do the exhaust noise calculations to find the optimum exhaust silencer attenuations (dBs) at all 8 frequencies, or, if you have a silencer with known dBs, you can verify if it suites your diesel engine. Of course, you have to define the criteria, such as 90 dBA at 1 m or 75 dBA at 7 m, and so on. You have to have the engine exhaust noise SPL or SWL data from the engine manufacturer. If not known, then you can use the exhaust noise estimator, which is part of NEC Acostix, to get the engine exhaust noise.
At the end, the module will give the results and summary of all calculations. You can always hide or show this calculation for the purpose of submittal to your customers.
ExTuner
The ExTuner is a tuning and design tool for reactive and dissipative exhaust silencers in accordance with ASHRAE guidelines. The silencer grade is selected from a drop-down list, and the size of the muffler (pipe size) is also selected from a drop-down list. The software will guide you on how to select the body diameter, length, number of chambers, how every chamber should be designed, what the size is, etc. The ExTuner is sold as a standalone software.
Inlet/Discharge Attenuators Design and Calculations:
This is a powerful design sheet that does two things at the same time. It designs the rectangular attenuator by finding its dimensional parameters and acoustic characteristics to achieve the noise attenuation from one side, and it gives the dimensional parameters that achieve the maximum allowable pressure drop across the attenuator air ducts.
The sheet can do 4 functions: design inlet attenuator, design discharge attenuator, verify inlet attenuator, and verify discharge attenuator.
You need to enter the engine surface noise SPL data, airflow data, noise criteria, and overall aperture height and width, and then you select the number of airways and the thickness of the splitters. Of course, there are rules for how to select them, which you can learn in our noise. You can fine-tune your selection to get the best results for acoustic and pressure drop performance. You can always select to show or hide the detailed calculations. The sheet allows you to select the acoustic material filling details and enter the average room absorption coefficient, which can be calculated by NEC Acostix.
The resultant static and insertion losses can vary from the ones obtained through tests by 1–3 dB in the low frequency and up to 3–5 dB in the higher frequencies, but the overall weighted dB could be within 2 dBA error in accordance with ISO standards. For more details, please contact support@najahengineering.com.
Training and Technical Support
You can attend any of the following courses that will enrich your knowledge and skills in noise control and sound attenuation design. We are proud that our industrial noise control training programs are classified among the top worldwide. Attendees are from all six continents.
AC-01 Industrial Noise Control and Sound Attenuation Design
A 3-day course organized publicly or in-house. This is 18 hours of training instruction and extensive design workshops covering all the concepts of industrial noise, sound insulation materials, and design of noise control modules for power generation, residential, HVAC, and other applications, and explains the Acostix software modules.
AC-02 Architectural Acoustics: Sound in free field and inside rooms, sound reverberation, acoustic materials, masonry walls and floors acoustics, building materials, sound calculations, and sound attenuation to achieve sound criteria. This training course is only available upon request.
AC-03 Design of Exhaust Silencers and HVAC Silencers to International Standards
AC-04 NEC Acostix® Software Training and Users’ Meeting
This is usually a one-day event that explains the fundamentals of acoustics and then goes through the Acostix® software modules and features.
You can register for any of the training courses online or contact training@najahengineering.com.
For technical support, you may contact support@najahengineering.com.
Free Field/Inside Room (Reverberant) Noise Calculations Tool:
Sometimes, you may need to calculate the noise in the free field if the noise is known at some location.
This sheet allows for noise calculations of SPL or SWL at different distances in the free field. You can either do the calculation for a single dB figure or over the eight (8) frequencies.